Место происхождения: | Китай |
Фирменное наименование: | SKYLINE |
Сертификация: | CE |
Номер модели: | SL-SGF01 |
Количество мин заказа: | 1 |
---|---|
Цена: | negoitable |
Упаковывая детали: | Фанерный корпус |
Время доставки: | 15 рабочих дней |
Условия оплаты: | T/T. |
Поставка способности: | 1 UNIT/MONTH |
Власть: | 220 В ± 10%50 Гц/180 Вт | освещение: | Автозажигание |
---|---|---|---|
Точность времени (разрешение): | 0,1 секунды | Время стабилизации температуры: | <3 минуты (800 ± 30) ℃ |
Диапазон регулирования потока: | От 100 до 1000 мл /мин | Высота факела: | От 20 мм до 100 мм (регулируемые) |
Выделить: | fire resistance tester for gypsum board,gypsum board flammability tester,paper gypsum board stability tester |
Attribute | Value |
---|---|
Power | 220V±10%50Hz/180W |
Lighting | Autoignition |
Timing accuracy (resolution) | 0.1 seconds |
Temperature stabilization time | <3 minutes (800±30) ℃ |
The flow regulation range | 100 to 1000 ml /Min |
Flame length | 20mm to 100mm(Adjustable) |
It is used for measuring plasterboard stability in case of fire, and can also be applied to other building materials, decoration materials, and fire prevention performance measurement.
The test involves drilling and processing under prescribed conditions. The sample is suspended between two fire nozzles with a support rod, making the fire nozzles perpendicular to the surface of the sample. Liquefied petroleum gas is used as the heat source to supply gas to the two burners of the fire stability tester. The distance between the burner nozzle and the plate surface is 30mm.
A load is suspended at the lower end of the specimen as per the standard and the burner is ignited. The temperature is measured at a distance of 5mm from the plate surface using a thermocouple. During the initial stage of the test, any carbonized protective paper that has fallen onto the thermocouple should be removed without shaking the sample.
Through adjustment, the temperature is controlled at (800±30)℃ within 3 minutes and maintained at this temperature throughout the test. Timing begins from the moment the specimen is exposed to fire until it breaks and fails. The time taken for each specimen to be burned off is recorded, and the minimum value among five specimens is taken as the fire stability of this group of specimens, accurate to 1 minute.
Place | Dimension | 700(W)×300(D)×600(H)mm |
---|---|---|
Weight | About 30 kg | |
Test table | Require no less than 1 meter height and a width of no less than 0.75 meters | |
Power Supply | Voltage | 220V±10%, 50HZ |
Power | 180W | |
Water Source | NA | |
Air Source | Liquefied petroleum gas (recommended to choose gas with better quality) | |
Pollutants | Dust | |
Ventilation requirements | The equipment needs to be placed in a fume hood or collected for flue gas and connected to the flue gas treatment and purification system | |
Other test requirements | Gas cylinder matching pressure reducing valve (capable of adjusting to 0.3 megapascals) |
Контактное лицо: Ms. Ivy Xie
Телефон: 86-13751491529
Факс: 86-769-38818154
EN 1957 Машины для испытания матрасов с PLC сенсорным экраном, интегрированный сервомотор
Тепломер конуса ISO 5660 AC220V для испытывать строительных материалов
Прибор теста тоннеля Стайнер оборудования для испытаний огня
Машина испытания удара места стула оборудования для испытаний мебели БИФМА 5,1